Description of the Chiller 20ft High Refrigerated Container

Passive Reefer Container
Our 20ft High Cube Refrigerated Container is a professional intermodal reefer designed for secure, long-distance transport and stable cold storage of temperature-sensitive cargo. With extra internal height, it delivers greater loading capacity and operational convenience than standard reefers.
Built with heavy-duty corrugated steel exterior, food-grade interior lining and high-density PU foam insulation, it ensures excellent thermal efficiency and structural durability. Equipped with a branded, low-consumption refrigeration unit, it maintains precise temperature control from -25°C to +25°C to suit fresh produce, seafood, meat, dairy, pharmaceuticals and other perishables.
Standard features include T-floor for enhanced air circulation, reliable door seals, CSC certification for global shipping, and intuitive digital controls for real-time temperature monitoring. Compact, versatile and energy-efficient, this high cube reefer is ideal for sea, road and rail logistics, as well as on-site cold storage.


Product Features of Container Chiller 20ft High Refrigerated Container

Active Reefer Container

Stable and Precise Temperature Control

The 20ft high refrigerated container is equipped with an advanced, fully automatic refrigeration system that supports a wide temperature regulation range, typically from -25°C to +25°C, allowing it to adapt to various cargo requirements. It maintains consistent internal temperature with minimal fluctuation, effectively preventing spoilage, deterioration, or structural changes caused by unstable environments. The integrated digital control panel enables real-time temperature monitoring, adjustment, and fault feedback, ensuring users can track operating status at any time. Whether for frozen goods such as meat, seafood, and ice cream, or chilled products including fruits, vegetables, dairy, and flowers, the unit provides reliable, graded temperature protection. Its high-airflow ventilation design ensures even cold air distribution throughout the container, eliminating hotspots and maintaining uniform quality across all cargo areas.

Modular Refrigerated Container

Robust Structural Design and High Durability

Constructed with high-strength corten steel and reinforced aluminum alloy components, the 20ft high refrigerated container offers exceptional structural stability and impact resistance. The extended height design increases internal loading volume while retaining standard external dimensions compatible with all major shipping, trucking, and port handling systems. The container features reinforced corner castings, heavy-duty base frames, and anti-corrosion surface treatment to withstand long-distance ocean voyages, repeated lifting, stacking, and outdoor exposure. Its insulated body uses high-density, closed-cell polyurethane foam with excellent thermal insulation performance, reducing cold loss and lowering energy consumption. The double-sealed rubber door gasket effectively blocks external heat and moisture, maintaining stable internal conditions and improving overall energy efficiency.

40ft HC Reefer Container Height

High Compatibility and Standardized Operational Flexibility

As a universal 20ft high cube unit, this refrigerated container fully complies with ISO international standards, making it suitable for container ships, rail transport, flatbed trucks, and terminal operations worldwide. It supports multi-modal transport without the need for reloading cargo, greatly improving logistics efficiency and reducing damage risks during transfer. The standardized dimensions allow seamless integration with existing cold-chain systems and storage facilities. The interior is equipped with adjustable T-bars, floor tracks, and optional cargo restraint systems to secure different types of goods and maximize space utilization. The wide-opening door design facilitates convenient loading, unloading, and manual inspection, while the smooth, easy-to-clean interior surface meets hygiene requirements for food and pharmaceutical logistics.

Refrigerated Container for Food Transport

Energy Saving, Environmental Protection and Low Maintenance

The refrigeration system adopts high-efficiency compressors, fans, and environmentally friendly refrigerants that comply with global environmental regulations, reducing ozone depletion potential and greenhouse gas emissions. The optimized insulation structure significantly reduces energy consumption compared with traditional refrigerated units, resulting in lower long-term operating costs. The system supports multiple power inputs, including maritime three-phase power, land-based generators, and shore power supplies, ensuring stable operation in different scenarios. Key components are designed for easy access and maintenance, with self-diagnostic functions that simplify troubleshooting and reduce downtime. Its reliable performance reduces the need for frequent repairs, making it a cost-effective solution for long-term rental, commercial transportation, and on-site cold storage.

Applications of Chiller 20ft High Refrigerated Container
Vaccine Storage Reefer Container

· PrFood processing workshops

· Cold stores and freezer rooms

· Cold chain logistics centres and distribution warehouses

· Pharmaceutical factories and cleanrooms

· Biological laboratories and sample repositories

· Flower preservation chambers

· Low-temperature storage for




  • PREVIOUS:Blast Freezer Refrigerated Container
  • NEXT:Chiller 20ft Refrigerated Shipping Container

  • Product Type Chiller 20ft Refrigerated Shipping Container
    Condition
    Brand New
    Floor
    Aluminum T-Floor
    Size
    10FT (3.05m), 20FT (6.1m), 40FT (12.2m), 45FT(13.7m)
    Application

    Store Fresh Vegetables, Store Fresh Fruits, Store FrozenFish, Store Frozen Meat

    Cooling Units
    Bitzer refrigeration unit
    Compressor
    Bitzer 4-cyinder
    Cooling Capacity
    5-50 kW
    Internal Temperature
    30'℃ to +30'℃(-22°Fto +86°F)
    Volume
    5.85mx2.23mx2.15m(15.76 CBM)
    Gross Weight
    17.5T
    Door Size
    2.3m x 2.1m
    Voltage
    220V/380V (single-phase/three-phase)
    Refrigerant
    R404A/R134a/R410A
    Insulation
    Polyurethane (PU) foam insulation
    Thickness
    50mm/75mm/100mm
    Certifications
    ISO 9001, CE,
    MOQ
    1PC
    Life Span
    ≥25 Years
    eolor
    customizable

    Comprehensive FAQ: Cold Storage Rooms & Walk-in Freezers

    Part 1: General Definitions & Types

    1. What is the difference between a Cold Storage Room (Chiller) and a Freezer Room?

    While both look structurally similar, the key difference lies in temperature range and application:

    • Chiller Room (Medium Temperature): Operates between 0°C and +5°C (32°F - 41°F). It is designed to preserve fresh products like vegetables, fruits, dairy, and beverages without freezing them. The goal is to slow down bacterial growth and enzymatic activity.

    • Freezer Room (Low Temperature): Operates between -18°C and -25°C (0°F - -13°F). It is designed to keep products frozen solid (meat, fish, ice cream). The refrigeration system requires more power, thicker insulation, and specific defrosting mechanisms compared to a chiller.

    2. What is a "Blast Freezer" and how does it differ from a standard freezer?

    A standard freezer is designed for holding already-frozen goods. A Blast Freezer (or Shock Freezer) is designed for processing.

    • Function: It uses high-velocity fans and powerful compressors to pull the temperature of fresh food down to -18°C core temperature extremely fast (usually within 4 to 6 hours).

    • Why use it? Rapid freezing creates "micro-crystals" inside the food cells. Slow freezing creates large jagged ice crystals that puncture cell walls, causing "drip loss" and mushy texture upon thawing. Blast freezing preserves the quality, texture, and nutritional value of the food.

    3. What is a "CA" (Controlled Atmosphere) Cold Store?

    A Controlled Atmosphere (CA) store is an advanced cold room typically used for long-term fruit storage (like apples, pears, or kiwis).

    • Mechanism: In addition to controlling temperature, a CA room tightly controls the gas composition of the air. It reduces Oxygen (O2) and increases Carbon Dioxide (CO2) and Nitrogen.

    • Benefit: This puts the fruit into a state of "hibernation," slowing down its respiration rate. This allows seasonal fruits to be stored for 6 to 9 months and sold year-round as if they were fresh.

    4. Can I use a standard air conditioner (AC) to cool a small cold room?

    No. This is a common mistake that leads to equipment failure.

    • Design Difference: Standard AC units are designed to cool air to roughly 18°C-22°C. They are not designed to handle the moisture load or the low temperatures of a cold room (0°C).

    • The Result: If you force an AC to run at 5°C, the evaporator coil will freeze up immediately because it lacks a defrost mechanism. Furthermore, the compressor is not designed for the pressure ratios required for refrigeration, leading to premature burnout.


    Part 2: Structure & Insulation

    5. Why are Polyurethane (PU) panels the industry standard for cold rooms?

    Polyurethane is used because it offers the best strength-to-insulation ratio.

    • Thermal Efficiency: PU has an extremely low thermal conductivity (K-value roughly 0.022 W/mK), meaning it keeps heat out very effectively.

    • Structural Integrity: When "sandwiched" between steel sheets, high-density PU foam (40-42 kg/m³) becomes rigid enough to support the ceiling and walls without needing an external skeleton for small to medium rooms.

    • Hygiene: PU panels are moisture-resistant and do not rot or harbor mold, which is critical for food safety standards (HACCP).

    6. How do I determine the correct panel thickness?

    Thickness depends on the temperature difference between the inside of the room and the outside ambient air. General guidelines are:

    • Chiller Rooms (0°C to +5°C): Typically use 75mm or 100mm thick panels.

    • Freezer Rooms (-18°C to -25°C): Typically use 120mm or 150mm thick panels.


    • Blast Freezers (-40°C): Require 150mm or 200mm panels.
      Using panels that are too thin causes condensation on the outside walls ("sweating") and forces the compressor to run continuously, wasting electricity.


    7. What is the "Cam-Lock" system and why is it important?

    Cam-locks are eccentric hook mechanisms embedded inside the foam of the panels.

    • Assembly: During installation, an Allen key is used to turn the lock, pulling the male and female edges of two panels tightly together.

    • Importance: This creates a tight mechanical seal without relying solely on glue or screws. It prevents "thermal bridges" (gaps where heat enters) and allows the cold room to be disassembled and moved to a new location in the future, which makes the asset modular and reusable.

    8. Does a cold room need a special floor?

    • Chiller Rooms: Often use the existing concrete floor if it is level, though an insulated floor is better for efficiency.

    • Freezer Rooms: Must have an insulated floor. If you build a freezer directly on concrete without insulation, the cold will penetrate downward, freezing the moisture in the soil below. This causes the ground to expand and heave (Frost Heave), which can crack the building's foundation and destroy the freezer floor.

    • Finish: The top surface usually uses checkered aluminum plates (anti-slip) or stainless steel for hygiene.


    Part 3: Refrigeration System & Components

    9. What is the difference between Monoblock and Split refrigeration units?

    • Monoblock (All-in-One): The compressor, condenser, and evaporator are built into a single compact unit that hangs through a hole in the wall.

      • Pros: Easiest to install (plug and play), no piping work needed.

      • Cons: Hot air is vented into the surrounding room (unless ducted), and they are generally limited to smaller capacities.

    • Split System: The condensing unit (noisy part) is placed outdoors, and the evaporator (cooling fan) is inside the room. Connected by copper piping.

      • Pros: Keeps noise and heat outside; supports much larger capacities and longer pipe runs.

      • Cons: Requires a certified technician to weld pipes and charge refrigerant.

    10. How does the defrost system work, and why is it necessary?

    Moisture in the air freezes onto the cold evaporator coils, forming ice. If this ice builds up, it blocks airflow, and the room gets warm.

    • Electric Defrost: Heater elements (like in a toaster) are embedded in the coil. The system pauses cooling, turns on heaters to melt the ice, and drains the water away. Common in freezers.

    • Air Defrost: In chiller rooms (above 2°C), the compressor stops, but the fans keep running. The room air melts the frost naturally.

    • Hot Gas Defrost: Hot refrigerant gas from the compressor is diverted backward through the evaporator. This is the fastest and most energy-efficient method but requires complex valving.

    11. Why do cold storage doors have heater wires?

    In freezer rooms, the temperature difference creates condensation around the door frame. This moisture can freeze, effectively welding the door shut.

    • Solution: A resistance heater wire is embedded in the door frame (or the door gasket). It keeps the perimeter just warm enough to prevent condensation and ice formation, ensuring the door can always be opened easily and the rubber seal doesn't tear.

    12. What is a Pressure Relief Port (or Decompression Valve)?

    When a freezer door is opened, warm air rushes in. When the door closes, that air cools down rapidly and shrinks (contracts).

    • The Physics: This contraction creates a vacuum inside the room. Without a relief port, the negative pressure can be so strong that you physically cannot pull the door open, or it might even collapse the ceiling panels inward.

    • The Valve: A small heated vent in the wall that equalizes the pressure automatically, allowing the door to open freely.

    13. Which refrigerants are currently recommended given environmental regulations?

    Old refrigerants like R22 are banned in most places.

    • Current Standard: R404A has been the standard for years but has a high Global Warming Potential (GWP) and is being phased out in Europe and parts of the US.

    • Modern Alternatives: R448A and R449A are popular, non-flammable replacements with lower GWP.

    • Future Proof: CO2 (R744) is becoming the standard for large industrial cold stores. It is natural, highly efficient, and future-proof against regulation, though the equipment is more expensive initially.


    Part 4: Usage & Maintenance

    14. How should I stack products inside the cold room?

    Proper airflow is critical. The cold air must circulate around the products to remove heat.

    • The Rule: Never block the evaporator fans. Leave at least 30-50cm of clearance in front of the fans.

    • Pallets: Keep products on pallets or shelving, not directly on the floor.

    • Walls: Leave a 5-10cm gap between the product and the wall panels to allow air to "envelope" the cargo.

    15. What is an "Air Curtain" and is it worth the cost?

    An air curtain is a fan unit mounted above the door that shoots a high-velocity stream of air downward when the door opens.

    • Function: It creates an invisible barrier that prevents cold air from falling out and warm air/insects from flying in.

    • Worth it? Yes. If the door is opened frequently, an air curtain can pay for itself in energy savings within 1-2 years by reducing the load on the compressor.

    16. Why is there ice building up on the floor or ceiling?

    • Ceiling Ice: Usually indicates an air leak in the roof panel joints or a lack of vapor barrier, allowing humid air to penetrate and freeze.

    • Floor Ice: Often caused by a damaged door seal (warm air enters at the bottom), or a blocked drain line. If the evaporator drain line heater fails, the water from the defrost cycle spills onto the floor and freezes.

    17. How often should the cold room be serviced?

    • Quarterly (Every 3 months): Clean the condenser coils (outdoor unit) to ensure heat rejection. Check door seals for tears.

    • Semi-Annually: Check refrigerant levels (sight glass), oil levels, and electrical connections.

    • Annually: Thorough inspection of the evaporator fans, drain heaters, and calibration of the temperature sensors.


    Part 5: Design & Energy Efficiency

    18. What is "Pull-Down Time"?

    Pull-down time is the duration required to lower the temperature of the products from their incoming temperature to the storage temperature.

    • Calculation: When sizing a unit, you must tell the engineer the "daily product turnover." Putting 10 tons of warm apples into a room requires a much larger compressor than holding 10 tons of already-cold apples.

    • Standard: A standard holding room is usually designed to handle a 10% daily product turnover with a pull-down time of 18-24 hours.

    19. How can I reduce the electricity bill for my cold storage?

    • Door Management: This is the #1 energy loss. Install automatic door closers or strip curtains (PVC strips).

    • LED Lighting: Use LED lights specifically designed for cold rooms. Old incandescent bulbs add heat to the room, which the compressor then has to remove.

    • Night Blind/Covers: If open display cabinets are used inside, cover them at night.

    • Smart Defrost: Upgrade to a controller that defrosts "on demand" rather than on a fixed timer.

    20. Can I monitor the cold room remotely?

    Yes, this is highly recommended for food safety compliance.

    • IoT Solutions: Modern controllers (like Dixell XWEB or Carel Boss) connect to the internet.

    • Alerts: You can receive SMS or email alerts if the temperature rises above a set limit ("High Temp Alarm"), if the door is left open, or if the power goes out. This allows you to save the inventory before it spoils.

    Leave Your Message
    Write your message here and send it to us

    Related PRODUCTS

    • LAC14-10.0 Cold Room indoor Unit

    • Potato Cold Room

    • Industrial Ice Making Screw Chiller

    • Strawberry Cold Room

    • Banana Cold Room

    • Spinach Cold Room

    Facebook

    Twitter

    Instagram

    Linkedin

    Pinterest

    Youtube

    whatsapp

    Email

    Phone