Shanghai Tech Limited Co.,Ltd

Anti-Frost Cold Room Indoor Unit

Short Description:

Choose our high-efficiency Anti-Frost Cold Room Indoor Unit for industrial and commercial cold storage! As a professional manufacturer, we supply energy saving, durable cold room anti-frost indoor units with custom service and favorable price. Our anti-frost indoor unit for cold room effectively prevents frost formation, ensuring stable cold room operation....


  • Model: LAC02-6.4
  • Power supply: 3N/380V/50HZ
  • Temperature used: -10°C ~ -25°C
  • Refrigeration capacity(kw): 2.2
  • Fin spacing(mm): 6.4

Product Details

Technical Data

FAQ

Product Tags

Description of Anti-Frost Cold Room Indoor Unit

Cold Room Indoor Unit Installation

in low-temperature storage environments. Built with wide‑fin‑spacing coils and intelligent defrost logic, it effectively suppresses frost buildup, maintains consistent heat exchange, and reduces downtime from frequent defrosting.
It uses high-efficiency inner-grooved copper tubes and low‑noise external rotor motors to deliver strong airflow and uniform cooling throughout the cold room. Supporting hot‑gas, electric, or water defrost, it adapts to chillers, freezers, and medium‑low‑temperature storage down to -25°C. The unit features a corrosion‑resistant metal cabinet, integrated drip tray, and smart temperature & defrost control for stable, energy‑saving operation.

Characteristics of Anti-Frost Cold Room Indoor Unit

Cold Room Indoor Unit Setup

Excellent Anti-Frost and Defrost Performance

The biggest advantage of this indoor unit is its professional anti-frost design. It uses an optimized evaporator coil structure and reasonable air duct layout to reduce moisture condensation and frost formation on the surface during operation. The unit supports multiple intelligent defrost modes including electric defrost, hot gas defrost, and air defrost, which can be automatically switched according to storage temperature, humidity, and running time.
Intelligent defrost control avoids excessive defrosting or insufficient defrosting. It effectively prevents ice from covering the coil and blocking air supply.

Cold Room Indoor Unit Maintenance

High-Efficiency Heat Exchange and Cooling Capacity

The indoor unit is equipped with a high-efficiency evaporator made of high-quality aluminum fins and copper tubes. The surface of the fins is specially treated to improve heat exchange efficiency and enhance corrosion resistance. The optimized tube and fin arrangement increases the heat exchange area while maintaining smooth air circulation, greatly improving the cooling speed.
Whether used in medium-temperature cold storage for fresh-keeping or low-temperature cold storage for freezing, the unit can quickly reduce the indoor temperature to the set value. It provides uniform cooling without local temperature differences, effectively maintaining the quality and shelf life of stored items.

Cold Room Indoor Unit Service

Stable and Reliable Operation System

The unit is equipped with a high-performance built-in fan and supporting electrical components. The fan features low noise, large air volume, and stable operation, adapting to long-term continuous working conditions. Key components are selected from well-known brands with strict quality control, ensuring stable performance under long-term low-temperature environments.
The shell and structural parts are made of corrosion-resistant and low-temperature-resistant materials, not easily deformed or rusted. The overall structure is sturdy and durable, reducing failure rates and maintenance times.

Cold Room Indoor Unit Repair

Intelligent Temperature Control and Easy Operation

This anti-frost indoor unit supports precise temperature control, usually with a temperature control accuracy within ±1℃. It can be connected to an intelligent temperature control system or PLC control cabinet for real-time monitoring and adjustment of cold room temperature. Users can set different temperature parameters according to stored goods, and the system will automatically adjust fan speed and cooling output.
The operation interface is simple and clear, easy to understand and operate. Even without professional training, users can complete parameter setting, mode switching, and status query.

Applications of Anti-Frost Cold Room Indoor Unit
Cold Room Indoor Unit Troubleshooting

· PrFood processing workshops

· Cold stores and freezer rooms

· Cold chain logistics centres and distribution warehouses

· Pharmaceutical factories and cleanrooms

· Biological laboratories and sample repositories

· Flower preservation chambers

· Low-temperature storage for




  • PREVIOUS:High Capacity Cold Room Indoor Unit
  • NEXT:Energy Efficient Cold Room Indoor Unit

  • Model LAC02-6.4

    Inlet refrigerant(mm)

    12

    Power supply

    3N/380V/50HZ Outlet refrigerant(mm)
    22
    Temperature used -10°C ~ -25°C Defrost
    Electric defrost
    Refrigeration capacity(kw) 2.2 Defrost heating(kw)
    2.0
    Fin spacing(mm) 6.4 Air delivery(m)
    9
    Heat transfer area(m2) 6.1

    Weight(kg)

    22
    Number of fans
    1 Operating weight(kg)
    25
    Motor power(w)
    120 Length(mm)
    780
    Fan diameter(mm)
    330 Width(mm)
    370
    Air volume(m3/h)
    1800 Height(mm)
    480

    Description of Unit Cooler Control

    Unit Cooler Control:

    Control encompasses both fan and defrost functions. The evaporator fan operates continuously within the system. Upon initiation of defrosting, the fan shuts off whilst the defrost heater activates.

    When the defrost timer reaches the preset time, the defrost heating element ceases operation
    when the defrost timer reaches the preset time and the internal temperature of the cooling unit reaches the target temperature, the fan commences operation.


    Defrost time setting of Unit Cooler:

    Defrosting occurs four times daily, with an initial default defrost duration of 50 minutes per cycle (adjustable based on actual frost thickness). Following each defrost cycle, the compressor and fan operation is determined by the storage temperature. Electric heating ceases when the interior reaches 15°C; the fan activates when the interior temperature drops to -8°C.

    Comprehensive FAQ: Refrigerated Cabinet

    I. Fundamentals and Components

    1. What is the primary function of a Cold Room Indoor Unit (Evaporator)?

    The primary function of the Cold Room Indoor Unit, commonly called the Evaporator or Unit Cooler, is to absorb heat from the cold room air. It achieves this by causing the low-pressure, low-temperature refrigerant within its coils to undergo a phase change (evaporation from liquid to gas), which is a highly endothermic (heat-absorbing) process, thereby lowering the temperature of the circulating air.

    2. What are the key components of a typical Unit Cooler?

    The main components are:

    • Evaporator Coil: The heat exchanger (copper/aluminum tubes with fins) where the refrigerant evaporates.

    • Fan Assembly: Uses axial or centrifugal fans to force air circulation across the coil and distribute cooled air throughout the room.

    • Defrost System: Typically electric heaters or hot gas lines to melt accumulated frost/ice.

    • Drain Pan (Drip Tray): Collects condensate and meltwater during the defrost cycle.

    • Casing: Corrosion-resistant enclosure (e.g., powder-coated steel, aluminum, stainless steel).

    3. Why is the fin spacing (fin pitch) important, and how does it relate to the room temperature?

    The fin pitch (distance between fins) affects both the heat transfer area and the rate of frost accumulation.

    • High-Temperature Rooms (e.g., above $0^\circ\text{C}$): Smaller fin pitches (e.g., $4.5-6 \text{ mm}$) are used to maximize heat transfer efficiency, as frost formation is minimal.

    • Low-Temperature Rooms (e.g., below $-18^\circ\text{C}$): Wider fin pitches (e.g., $8-12 \text{ mm}$) are necessary to accommodate a thicker frost layer before it significantly impedes airflow, thereby prolonging the time between necessary defrost cycles.

    4. What material is commonly used for evaporator coils and why?

    Copper tubing and aluminum fins are the most common combination due to their excellent thermal conductivity and cost-effectiveness. Stainless steel is sometimes used in highly corrosive environments (e.g., seafood processing) but is more expensive. The fins are bonded to the tubes to ensure maximum heat transfer area.

    5. What is "superheat," and why is it monitored at the evaporator outlet?

    Superheat is the amount of heat added to the refrigerant vapor after it has fully evaporated. It is measured as the temperature of the vapor leaving the evaporator coil minus the saturation temperature (boiling point) of the refrigerant at the evaporator pressure. Maintaining a controlled level of superheat (typically $4 \text{K}$ to $7 \text{K}$) ensures that no liquid refrigerant (liquid slugging) returns to the compressor, which would cause severe damage.

    II. Operation and Performance

    6. How is the cooling capacity (refrigeration capacity) of an evaporator rated?

    The cooling capacity is rated in kW or BTU/hr and is primarily determined by:

    • The temperature difference between the cold room air and the refrigerant evaporation temperature ($\Delta t$).

    • The airflow rate of the fans ($\text{m}^3/\text{h}$ or $\text{CFM}$).

    • The heat transfer surface area (coil size, fin pitch, and design).

    • Crucially: Evaporator capacity is always specified for a given TD (Temperature Difference).

    7. What is the "TD" (Temperature Difference) in relation to the evaporator?

    The TD is the difference between the cold room air temperature and the refrigerant's evaporation temperature ($\text{TD} = T_\text{air} - T_\text{evaporation}$). A smaller TD generally results in higher air humidity and better product quality (less dehydration), but requires a physically larger and more expensive evaporator. A larger TD leads to higher dehydration rates and potentially better energy efficiency but can stress the stored product.

    8. How does frost formation impact the efficiency of the evaporator?

    Frost formation has two major negative impacts:

    • Insulation: The layer of ice acts as an insulator, significantly reducing the heat transfer rate from the air to the refrigerant.

    • Airflow Restriction: The frost clogs the spaces between the fins, dramatically increasing the fan's static pressure and reducing the airflow, leading to poor heat absorption and temperature gradients in the room.

    9. What are the common types of defrost systems used in cold room evaporators?

    The three most common types are:

    • Electric Defrost: Uses electric resistance heaters (sheathed stainless steel elements) embedded within the coil and drain pan. It is the most common and reliable method but consumes significant electrical energy.

    • Hot Gas Defrost: Diverts the high-pressure, high-temperature discharge gas from the compressor into the evaporator coil, using the refrigerant's heat to melt the frost. This is highly efficient and quick but adds complexity to the piping and control system.

    • Air Defrost: Used only in high-temperature rooms (above $0^\circ\text{C}$), where the fans are simply run without refrigeration, allowing the warmer room air to melt the light frost.

    10. Why is it important to insulate the drain pan?

    Insulating or adopting a double-skin design for the drain pan prevents external condensation (sweating) on the pan's underside. If the pan's outer surface is exposed to the humid, slightly warmer room air, water will condense and drip onto the floor or product, which is a major hygiene and safety concern.

    III. Selection and Installation

    11. What is "air throw" or "air projection," and why is it important during installation?

    Air throw is the distance the cooled air jet can effectively travel from the evaporator fans before its velocity and cooling effect diminish. A Unit Cooler must be selected with sufficient air throw to ensure the cooled air reaches the furthest wall of the cold room and promotes uniform air distribution, preventing the formation of warm spots or temperature gradients.

    12. What factors must be considered when selecting an evaporator model?

    Selection must be based on:

    • Required Cooling Capacity: Must match the total calculated heat load (kW).

    • Cold Room Temperature: Dictates the TD and required fin pitch/defrost type.

    • Air Throw/Fan Type: Must suit the dimensions of the room (especially length).

    • Defrost Type: Electric, hot gas, or air defrost.

    • Refrigerant Type: Must be compatible with the system (e.g., R-404A, R-448A, $\text{CO}_2$).

    • Installation Height/Access: Physical size and maintenance clearances.

    13. What is the role of the expansion valve (TXV/EEV) in relation to the indoor unit?

    The Expansion Valve (TXV - Thermostatic Expansion Valve or EEV - Electronic Expansion Valve) is typically installed just before the evaporator. Its role is to:

    • Throttle (Reduce) the pressure of the liquid refrigerant from the condensing unit.

    • Meter (Control) the flow rate of liquid refrigerant into the evaporator coil.

    • It ensures the evaporator coil is fed with the correct amount of refrigerant to maintain the desired superheat (ensure all liquid evaporates before leaving the coil).

    14. How should the drain line be installed to prevent freezing in a freezer room?

    In low-temperature rooms, the drain line must be installed with a continuous downward slope and equipped with heat tracing cable (electric heating wire) along its entire length, especially where it exits the cold room boundary. A trap (U-bend) may be necessary but must also be heated to prevent the meltwater from freezing and blocking the line.

    15. What are the advantages of using variable speed fans on the indoor unit?

    Variable speed fans (often controlled by EC motors) offer several benefits:

    • Energy Savings: The fan speed can be reduced once the setpoint temperature is reached, drastically cutting power consumption.

    • Humidity Control: Lower fan speeds result in a smaller TD, which helps maintain higher relative humidity, reducing product dehydration (weight loss).

    • Noise Reduction: Lower speeds significantly decrease operational noise.

    IV. Maintenance and Troubleshooting

    16. What is the most common reason for a cold room to be running warm despite the unit running continuously?

    The most common reasons are:

    • Severe Frosting: Excessive frost on the coil due to a defrost system failure or inadequate frequency, severely blocking airflow and heat transfer.

    • Low Refrigerant Charge: Insufficient refrigerant in the system reduces the capacity of both the condenser and evaporator.

    • Dirty Coil: Dust, dirt, or debris on the coil surface acting as an insulator.

    • Air Leakage: Excessive infiltration of warm, humid ambient air through poorly sealed doors or panels.

    17. Why is regular cleaning of the evaporator coil necessary?

    Regular cleaning is vital because dust, dirt, or mold can settle on the fins. This debris acts as an insulator, reducing the coil's heat transfer efficiency. In food storage, it is also a critical hygiene requirement to prevent the growth of bacteria and cross-contamination.

    18. How often should the defrost cycle be initiated?

    The frequency depends on the room temperature, the product stored, and the ambient conditions (how frequently the doors open).

    • General Practice: Typically 2 to 6 defrost cycles per 24 hours.

    • High-Humidity Applications: More frequent defrosts (e.g., every 3-4 hours) may be required to prevent rapid frost buildup. The goal is to defrost before the frost layer causes a $20-30%$ reduction in cooling capacity.

    19. What should be done if water is dripping from the evaporator casing outside of the defrost cycle?

    This is usually caused by sweating (external condensation). The solution involves:

    • Checking Drain Pan Insulation: Ensure the drain pan's exterior surface is not exposed to the room air.

    • Checking Casing Integrity: Ensure the main unit casing is well-insulated, and no cold air is leaking through seams to cool the external surface.

    • Inspecting for Blockages: Ensure the drain line is not partially blocked, causing water to back up and overflow.

    20. What is the distinction between a 'Unit Cooler' and a 'Coil Unit'?

    While often used interchangeably:

    • Coil Unit (Evaporator Coil): Refers specifically to the heat exchanger component (tubes and fins) itself.

    • Unit Cooler (Cold Room Indoor Unit): Refers to the complete assembly, which includes the coil, fans, casing, drip tray, and often the defrost heaters—a functional, ready-to-install product.



    Leave Your Message
    Write your message here and send it to us

    Related PRODUCTS

    • High-Efficiency Screw Compressor

    • HVAC commercial cooling tower system design

    • Energy Saving Low Temp Cooling Plant

    • Cold Room Food Storage

    • Quick Freezing Tunnel Screw Chiller

    • Screw Type Chiller

    Facebook

    Twitter

    Instagram

    Linkedin

    Pinterest

    Youtube

    whatsapp

    Email

    Phone