Shanghai Tech Limited Co.,Ltd

Precision Temperature Control Cold Storage Indoor Unit

Short Description:

Supply high-quality Precision Temperature Control Cold Storage Indoor Unit with accurate temp regulation, energy saving and stable performance. Ideal for commercial, industrial cold storage & cold room in logistics, food processing. Factory direct, customizable for all your cooling needs....


  • Model: LAC02-6.4
  • Power supply: 3N/380V/50HZ
  • Temperature used: -10°C ~ -25°C
  • Refrigeration capacity(kw): 2.2
  • Fin spacing(mm): 6.4

Product Details

Technical Data

FAQ

Product Tags

Description of Precision Temperature Control Cold Storage Indoor Unit

Cold Room Indoor Unit for Sale

This precision cold storage indoor unit is engineered to deliver stable, accurate cooling for temperature-sensitive goods in commercial and industrial cold rooms. Built with high-efficiency heat exchangers, intelligent digital controls, and reliable refrigeration components, it maintains tight temperature uniformity while lowering energy use and operational noise.
Designed for ceiling or wall mounting, its compact structure saves space and simplifies installation and maintenance. Advanced defrost logic and anti-frost technology keep coils clear and performance consistent, even in long‑running low‑temperature environments.

Characteristics of Precision Temperature Control Cold Storage Indoor Unit

Wholesale Cold Room Indoor Unit

Ultra-High Precision Temperature Control

This cold storage indoor unit is built around a core design of stable and precise temperature regulation, making it ideal for temperature‑sensitive goods storage in food, pharmaceutical, chemical, and electronic industries. It adopts an advanced microprocessor‑based PID control system paired with high‑precision platinum resistance temperature sensors, delivering real‑time monitoring with an error range as low as ±0.5°C. The unit supports a wide operating temperature span from -35°C to +15°C, covering deep freezing, medium‑temperature cooling, and constant‑temperature preservation. It automatically adjusts cooling output based on real‑time heat load changes, eliminating temperature overshoot or undershoot. Uniform airflow distribution ensures consistent temperature across the entire storage space, avoiding local hot or cold spots.

Affordable Cold Room Indoor Unit

High-Efficiency Energy-Saving Performance

Engineered for low energy consumption and high cooling efficiency, the unit integrates multiple energy‑saving technologies to lower long‑term operating costs. It uses high‑efficiency rotary or scroll compressors with stable performance and low power consumption. The evaporator uses enhanced heat‑exchange copper tubes and aluminum fins with optimized spacing, boosting heat transfer efficiency and reducing energy waste. An electronic expansion valve enables precise refrigerant flow control, improving system response speed and saving up to 30% energy compared to traditional thermal expansion valves.

Cost Effective Cold Room Indoor Unit

Stable and Reliable Operation

Designed for 24/7 continuous duty in harsh cold‑storage environments, the unit ensures long‑term stability and minimal downtime. Key components use branded, rigorously tested parts for durability. The casing is made of corrosion‑resistant aluminum‑magnesium alloy or stainless steel with powder coating, preventing rust and extending service life. A dual‑drip tray with inclined edges collects condensate smoothly to avoid water accumulation or icing. The unit includes complete protection functions: overcurrent, overload, high/low pressure, phase loss, and sensor fault protection, automatically triggering alarms and shutting down if abnormalities occur.

High Quality Cold Room Indoor Unit

Compact Design and Easy Installation & Maintenance

With a compact, lightweight structure, the unit saves space and supports ceiling or wall mounting to fit various cold‑room layouts. Installation is fast with standard mounting brackets and accessories. Modular design groups core components for easy access, simplifying routine checks, cleaning, and part replacement. The evaporator and fan assembly are easy to disassemble for cleaning to maintain heat‑exchange efficiency. Low maintenance requirements reduce labor and downtime. Smooth, hygienic surfaces are easy to clean and meet health standards for food and pharmaceutical storage.

Applications of Precision Temperature Control Cold Storage Indoor Unit
Trusted Cold Room Indoor Unit

· PrFood processing workshops

· Cold stores and freezer rooms

· Cold chain logistics centres and distribution warehouses

· Pharmaceutical factories and cleanrooms

· Biological laboratories and sample repositories

· Flower preservation chambers

· Low-temperature storage for




  • PREVIOUS:Food Storage Cold Room Indoor Unit
  • NEXT:Custom Cold Room Indoor Unit

  • Model LAC02-6.4

    Inlet refrigerant(mm)

    12

    Power supply

    3N/380V/50HZ Outlet refrigerant(mm)
    22
    Temperature used -10°C ~ -25°C Defrost
    Electric defrost
    Refrigeration capacity(kw) 2.2 Defrost heating(kw)
    2.0
    Fin spacing(mm) 6.4 Air delivery(m)
    9
    Heat transfer area(m2) 6.1

    Weight(kg)

    22
    Number of fans
    1 Operating weight(kg)
    25
    Motor power(w)
    120 Length(mm)
    780
    Fan diameter(mm)
    330 Width(mm)
    370
    Air volume(m3/h)
    1800 Height(mm)
    480

    Description of Unit Cooler Control

    Unit Cooler Control:

    Control encompasses both fan and defrost functions. The evaporator fan operates continuously within the system. Upon initiation of defrosting, the fan shuts off whilst the defrost heater activates.

    When the defrost timer reaches the preset time, the defrost heating element ceases operation
    when the defrost timer reaches the preset time and the internal temperature of the cooling unit reaches the target temperature, the fan commences operation.


    Defrost time setting of Unit Cooler:

    Defrosting occurs four times daily, with an initial default defrost duration of 50 minutes per cycle (adjustable based on actual frost thickness). Following each defrost cycle, the compressor and fan operation is determined by the storage temperature. Electric heating ceases when the interior reaches 15°C; the fan activates when the interior temperature drops to -8°C.

    Comprehensive FAQ: Refrigerated Cabinet

    I. Fundamentals and Components

    1. What is the primary function of a Cold Room Indoor Unit (Evaporator)?

    The primary function of the Cold Room Indoor Unit, commonly called the Evaporator or Unit Cooler, is to absorb heat from the cold room air. It achieves this by causing the low-pressure, low-temperature refrigerant within its coils to undergo a phase change (evaporation from liquid to gas), which is a highly endothermic (heat-absorbing) process, thereby lowering the temperature of the circulating air.

    2. What are the key components of a typical Unit Cooler?

    The main components are:

    • Evaporator Coil: The heat exchanger (copper/aluminum tubes with fins) where the refrigerant evaporates.

    • Fan Assembly: Uses axial or centrifugal fans to force air circulation across the coil and distribute cooled air throughout the room.

    • Defrost System: Typically electric heaters or hot gas lines to melt accumulated frost/ice.

    • Drain Pan (Drip Tray): Collects condensate and meltwater during the defrost cycle.

    • Casing: Corrosion-resistant enclosure (e.g., powder-coated steel, aluminum, stainless steel).

    3. Why is the fin spacing (fin pitch) important, and how does it relate to the room temperature?

    The fin pitch (distance between fins) affects both the heat transfer area and the rate of frost accumulation.

    • High-Temperature Rooms (e.g., above $0^\circ\text{C}$): Smaller fin pitches (e.g., $4.5-6 \text{ mm}$) are used to maximize heat transfer efficiency, as frost formation is minimal.

    • Low-Temperature Rooms (e.g., below $-18^\circ\text{C}$): Wider fin pitches (e.g., $8-12 \text{ mm}$) are necessary to accommodate a thicker frost layer before it significantly impedes airflow, thereby prolonging the time between necessary defrost cycles.

    4. What material is commonly used for evaporator coils and why?

    Copper tubing and aluminum fins are the most common combination due to their excellent thermal conductivity and cost-effectiveness. Stainless steel is sometimes used in highly corrosive environments (e.g., seafood processing) but is more expensive. The fins are bonded to the tubes to ensure maximum heat transfer area.

    5. What is "superheat," and why is it monitored at the evaporator outlet?

    Superheat is the amount of heat added to the refrigerant vapor after it has fully evaporated. It is measured as the temperature of the vapor leaving the evaporator coil minus the saturation temperature (boiling point) of the refrigerant at the evaporator pressure. Maintaining a controlled level of superheat (typically $4 \text{K}$ to $7 \text{K}$) ensures that no liquid refrigerant (liquid slugging) returns to the compressor, which would cause severe damage.

    II. Operation and Performance

    6. How is the cooling capacity (refrigeration capacity) of an evaporator rated?

    The cooling capacity is rated in kW or BTU/hr and is primarily determined by:

    • The temperature difference between the cold room air and the refrigerant evaporation temperature ($\Delta t$).

    • The airflow rate of the fans ($\text{m}^3/\text{h}$ or $\text{CFM}$).

    • The heat transfer surface area (coil size, fin pitch, and design).

    • Crucially: Evaporator capacity is always specified for a given TD (Temperature Difference).

    7. What is the "TD" (Temperature Difference) in relation to the evaporator?

    The TD is the difference between the cold room air temperature and the refrigerant's evaporation temperature ($\text{TD} = T_\text{air} - T_\text{evaporation}$). A smaller TD generally results in higher air humidity and better product quality (less dehydration), but requires a physically larger and more expensive evaporator. A larger TD leads to higher dehydration rates and potentially better energy efficiency but can stress the stored product.

    8. How does frost formation impact the efficiency of the evaporator?

    Frost formation has two major negative impacts:

    • Insulation: The layer of ice acts as an insulator, significantly reducing the heat transfer rate from the air to the refrigerant.

    • Airflow Restriction: The frost clogs the spaces between the fins, dramatically increasing the fan's static pressure and reducing the airflow, leading to poor heat absorption and temperature gradients in the room.

    9. What are the common types of defrost systems used in cold room evaporators?

    The three most common types are:

    • Electric Defrost: Uses electric resistance heaters (sheathed stainless steel elements) embedded within the coil and drain pan. It is the most common and reliable method but consumes significant electrical energy.

    • Hot Gas Defrost: Diverts the high-pressure, high-temperature discharge gas from the compressor into the evaporator coil, using the refrigerant's heat to melt the frost. This is highly efficient and quick but adds complexity to the piping and control system.

    • Air Defrost: Used only in high-temperature rooms (above $0^\circ\text{C}$), where the fans are simply run without refrigeration, allowing the warmer room air to melt the light frost.

    10. Why is it important to insulate the drain pan?

    Insulating or adopting a double-skin design for the drain pan prevents external condensation (sweating) on the pan's underside. If the pan's outer surface is exposed to the humid, slightly warmer room air, water will condense and drip onto the floor or product, which is a major hygiene and safety concern.

    III. Selection and Installation

    11. What is "air throw" or "air projection," and why is it important during installation?

    Air throw is the distance the cooled air jet can effectively travel from the evaporator fans before its velocity and cooling effect diminish. A Unit Cooler must be selected with sufficient air throw to ensure the cooled air reaches the furthest wall of the cold room and promotes uniform air distribution, preventing the formation of warm spots or temperature gradients.

    12. What factors must be considered when selecting an evaporator model?

    Selection must be based on:

    • Required Cooling Capacity: Must match the total calculated heat load (kW).

    • Cold Room Temperature: Dictates the TD and required fin pitch/defrost type.

    • Air Throw/Fan Type: Must suit the dimensions of the room (especially length).

    • Defrost Type: Electric, hot gas, or air defrost.

    • Refrigerant Type: Must be compatible with the system (e.g., R-404A, R-448A, $\text{CO}_2$).

    • Installation Height/Access: Physical size and maintenance clearances.

    13. What is the role of the expansion valve (TXV/EEV) in relation to the indoor unit?

    The Expansion Valve (TXV - Thermostatic Expansion Valve or EEV - Electronic Expansion Valve) is typically installed just before the evaporator. Its role is to:

    • Throttle (Reduce) the pressure of the liquid refrigerant from the condensing unit.

    • Meter (Control) the flow rate of liquid refrigerant into the evaporator coil.

    • It ensures the evaporator coil is fed with the correct amount of refrigerant to maintain the desired superheat (ensure all liquid evaporates before leaving the coil).

    14. How should the drain line be installed to prevent freezing in a freezer room?

    In low-temperature rooms, the drain line must be installed with a continuous downward slope and equipped with heat tracing cable (electric heating wire) along its entire length, especially where it exits the cold room boundary. A trap (U-bend) may be necessary but must also be heated to prevent the meltwater from freezing and blocking the line.

    15. What are the advantages of using variable speed fans on the indoor unit?

    Variable speed fans (often controlled by EC motors) offer several benefits:

    • Energy Savings: The fan speed can be reduced once the setpoint temperature is reached, drastically cutting power consumption.

    • Humidity Control: Lower fan speeds result in a smaller TD, which helps maintain higher relative humidity, reducing product dehydration (weight loss).

    • Noise Reduction: Lower speeds significantly decrease operational noise.

    IV. Maintenance and Troubleshooting

    16. What is the most common reason for a cold room to be running warm despite the unit running continuously?

    The most common reasons are:

    • Severe Frosting: Excessive frost on the coil due to a defrost system failure or inadequate frequency, severely blocking airflow and heat transfer.

    • Low Refrigerant Charge: Insufficient refrigerant in the system reduces the capacity of both the condenser and evaporator.

    • Dirty Coil: Dust, dirt, or debris on the coil surface acting as an insulator.

    • Air Leakage: Excessive infiltration of warm, humid ambient air through poorly sealed doors or panels.

    17. Why is regular cleaning of the evaporator coil necessary?

    Regular cleaning is vital because dust, dirt, or mold can settle on the fins. This debris acts as an insulator, reducing the coil's heat transfer efficiency. In food storage, it is also a critical hygiene requirement to prevent the growth of bacteria and cross-contamination.

    18. How often should the defrost cycle be initiated?

    The frequency depends on the room temperature, the product stored, and the ambient conditions (how frequently the doors open).

    • General Practice: Typically 2 to 6 defrost cycles per 24 hours.

    • High-Humidity Applications: More frequent defrosts (e.g., every 3-4 hours) may be required to prevent rapid frost buildup. The goal is to defrost before the frost layer causes a $20-30%$ reduction in cooling capacity.

    19. What should be done if water is dripping from the evaporator casing outside of the defrost cycle?

    This is usually caused by sweating (external condensation). The solution involves:

    • Checking Drain Pan Insulation: Ensure the drain pan's exterior surface is not exposed to the room air.

    • Checking Casing Integrity: Ensure the main unit casing is well-insulated, and no cold air is leaking through seams to cool the external surface.

    • Inspecting for Blockages: Ensure the drain line is not partially blocked, causing water to back up and overflow.

    20. What is the distinction between a 'Unit Cooler' and a 'Coil Unit'?

    While often used interchangeably:

    • Coil Unit (Evaporator Coil): Refers specifically to the heat exchanger component (tubes and fins) itself.

    • Unit Cooler (Cold Room Indoor Unit): Refers to the complete assembly, which includes the coil, fans, casing, drip tray, and often the defrost heaters—a functional, ready-to-install product.



    Leave Your Message
    Write your message here and send it to us

    Related PRODUCTS

    • Customized Mobile Cold Room

    • Stainless Steel Cold Room Indoor Unit

    • industrial integrated chiller

    • Low Temp Water Cooled Screw Chiller

    • commercial integrated chiller

    • Cherry Tomato Cold Storage

    Facebook

    Twitter

    Instagram

    Linkedin

    Pinterest

    Youtube

    whatsapp

    Email

    Phone