Shanghai Tech Limited Co.,Ltd

20ft Good Compressor Refrigerated Container

Short Description:

Looking for a reliable container cold room? We offer 20ft and 40ft mobile cold storage solutions with precise temperature control. Get a free quote today!...


  • Product Type: 20ft Good Compressor Refrigerated Container
  • Condition: Brand New
  • Floor: Aluminum T-Floor
  • Size: 10FT (3.05m), 20FT (6.1m), 40FT (12.2m), 45FT(13.7m)
  • Application: Store Fresh Vegetables, Store Fresh Fruits, Store FrozenFish, Store Frozen Meat

Product Details

Technical Data

FAQ

Product Tags

Description of the 20ft Good Compressor Refrigerated Container

Container Cold Room Manufacturer
Engineered for uncompromising temperature stability and global logistics reliability, our 20ft Refrigerated Container with a premium high-efficiency compressor delivers industry-leading cooling performance for perishable cargo, pharmaceuticals, and temperature-sensitive goods. Built to ISO 6346 (22R1) standards and optimized for intermodal transport—sea, rail, road, and on-site storage—this unit combines rugged durability, energy efficiency, and precision climate control to protect your high-value shipments across extreme ocean and land conditions, including the stringent compliance requirements of the European market.

Product Features of Container 20ft Good Compressor Refrigerated Container

Buy Refrigerated Container

Stable and Efficient Cooling Performance

The 20ft refrigerated container is equipped with a high-performance compressor system that ensures stable and reliable cooling under various working conditions. The compressor adopts an advanced design with strong cooling capacity, fast temperature drop, and high operating efficiency. It can quickly lower the internal temperature of the container to the set level and maintain stable operation for a long time. The temperature control range is wide, usually from -25°C to +25°C, which can meet the refrigeration, freezing, and constant temperature storage needs of different types of goods. Whether it is fresh agricultural products, seafood, meat, or pharmaceutical products that require strict temperature control, this container can provide a suitable temperature environment to ensure product quality and freshness. The optimized refrigeration pipeline and air circulation system make the internal temperature distribution uniform, avoiding local temperature differences that may affect the quality of goods.

Reefer Container Price

Compact and Standard 20ft Structure

As a standard 20-foot container, this refrigerated unit has a universal size that matches international transportation standards. It is highly compatible with various modes of transportation including ocean shipping, land trucking, and railway transportation, and can be smoothly connected to different logistics links. The compact structure does not take up too much space, making it easy to load, unload, stack, and transfer. The internal usable volume is reasonable, which can meet the medium-volume cargo storage and transportation needs of enterprises. The external dimensions are strictly in line with international container specifications, so it can be used on all kinds of ships, trucks, and container yards without additional modification, greatly improving the flexibility and convenience of logistics and transportation.

Custom Cold Storage Container

Durable and Reliable Structural Design

The overall structure of the 20ft refrigerated container is sturdy and durable, made of high-strength steel and thermal insulation materials with strong compression and impact resistance. It can resist extrusion and collision during long-distance transportation and complex working environments, ensuring the safety of the container body and internal goods. The surface is treated with anti-corrosion and anti-rust technology, which can adapt to humid, salt-spray, and other harsh marine and outdoor environments, extending the service life of the container. The door structure is tight and firm, with good sealing performance, which can effectively prevent external air, moisture, and dust from entering the interior, maintaining the stability of the internal refrigeration environment and reducing energy loss.

Turnkey Cold Storage Solutions

Excellent Thermal Insulation Effect

The container uses high-density thermal insulation materials with low thermal conductivity, which can effectively isolate the heat exchange between the inside and outside. Even in high-temperature outdoor environments, it can slow down the rise of internal temperature and reduce the operating load of the compressor. The good thermal insulation performance not only ensures the stability of the refrigeration effect but also reduces energy consumption and operating costs. The thermal insulation layer is evenly distributed and firmly combined with the container body, not easy to fall off or deform, maintaining a long-term and stable thermal insulation effect. This feature is particularly important for long-distance transportation, as it can keep the goods in a stable temperature environment for a long time and reduce quality risks.

Applications of 20ft Good Compressor Refrigerated Container
Container Cold Room, Refrigerated Container

· PrFood processing workshops

· Cold stores and freezer rooms

· Cold chain logistics centres and distribution warehouses

· Pharmaceutical factories and cleanrooms

· Biological laboratories and sample repositories

· Flower preservation chambers

· Low-temperature storage for


  • PREVIOUS:Cold room swing doors
  • NEXT:Automatic-Cold-Room-Control-Panel-Changeover-Switch

  • Product Type 20ft Good Compressor Refrigerated Container
    Condition
    Brand New
    Floor
    Aluminum T-Floor
    Size
    10FT (3.05m), 20FT (6.1m), 40FT (12.2m), 45FT(13.7m)
    Application

    Store Fresh Vegetables, Store Fresh Fruits, Store FrozenFish, Store Frozen Meat

    Cooling Units
    Bitzer refrigeration unit
    Compressor
    Bitzer 4-cyinder
    Cooling Capacity
    5-50 kW
    Internal Temperature
    30'℃ to +30'℃(-22°Fto +86°F)
    Volume
    5.85mx2.23mx2.15m(15.76 CBM)
    Gross Weight
    17.5T
    Door Size
    2.3m x 2.1m
    Voltage
    220V/380V (single-phase/three-phase)
    Refrigerant
    R404A/R134a/R410A
    Insulation
    Polyurethane (PU) foam insulation
    Thickness
    50mm/75mm/100mm
    Certifications
    ISO 9001, CE,
    MOQ
    1PC
    Life Span
    ≥25 Years
    eolor
    customizable

    Comprehensive FAQ: Cold Storage Rooms & Walk-in Freezers

    Part 1: General Definitions & Types

    1. What is the difference between a Cold Storage Room (Chiller) and a Freezer Room?

    While both look structurally similar, the key difference lies in temperature range and application:

    • Chiller Room (Medium Temperature): Operates between 0°C and +5°C (32°F - 41°F). It is designed to preserve fresh products like vegetables, fruits, dairy, and beverages without freezing them. The goal is to slow down bacterial growth and enzymatic activity.

    • Freezer Room (Low Temperature): Operates between -18°C and -25°C (0°F - -13°F). It is designed to keep products frozen solid (meat, fish, ice cream). The refrigeration system requires more power, thicker insulation, and specific defrosting mechanisms compared to a chiller.

    2. What is a "Blast Freezer" and how does it differ from a standard freezer?

    A standard freezer is designed for holding already-frozen goods. A Blast Freezer (or Shock Freezer) is designed for processing.

    • Function: It uses high-velocity fans and powerful compressors to pull the temperature of fresh food down to -18°C core temperature extremely fast (usually within 4 to 6 hours).

    • Why use it? Rapid freezing creates "micro-crystals" inside the food cells. Slow freezing creates large jagged ice crystals that puncture cell walls, causing "drip loss" and mushy texture upon thawing. Blast freezing preserves the quality, texture, and nutritional value of the food.

    3. What is a "CA" (Controlled Atmosphere) Cold Store?

    A Controlled Atmosphere (CA) store is an advanced cold room typically used for long-term fruit storage (like apples, pears, or kiwis).

    • Mechanism: In addition to controlling temperature, a CA room tightly controls the gas composition of the air. It reduces Oxygen (O2) and increases Carbon Dioxide (CO2) and Nitrogen.

    • Benefit: This puts the fruit into a state of "hibernation," slowing down its respiration rate. This allows seasonal fruits to be stored for 6 to 9 months and sold year-round as if they were fresh.

    4. Can I use a standard air conditioner (AC) to cool a small cold room?

    No. This is a common mistake that leads to equipment failure.

    • Design Difference: Standard AC units are designed to cool air to roughly 18°C-22°C. They are not designed to handle the moisture load or the low temperatures of a cold room (0°C).

    • The Result: If you force an AC to run at 5°C, the evaporator coil will freeze up immediately because it lacks a defrost mechanism. Furthermore, the compressor is not designed for the pressure ratios required for refrigeration, leading to premature burnout.


    Part 2: Structure & Insulation

    5. Why are Polyurethane (PU) panels the industry standard for cold rooms?

    Polyurethane is used because it offers the best strength-to-insulation ratio.

    • Thermal Efficiency: PU has an extremely low thermal conductivity (K-value roughly 0.022 W/mK), meaning it keeps heat out very effectively.

    • Structural Integrity: When "sandwiched" between steel sheets, high-density PU foam (40-42 kg/m³) becomes rigid enough to support the ceiling and walls without needing an external skeleton for small to medium rooms.

    • Hygiene: PU panels are moisture-resistant and do not rot or harbor mold, which is critical for food safety standards (HACCP).

    6. How do I determine the correct panel thickness?

    Thickness depends on the temperature difference between the inside of the room and the outside ambient air. General guidelines are:

    • Chiller Rooms (0°C to +5°C): Typically use 75mm or 100mm thick panels.

    • Freezer Rooms (-18°C to -25°C): Typically use 120mm or 150mm thick panels.


    • Blast Freezers (-40°C): Require 150mm or 200mm panels.
      Using panels that are too thin causes condensation on the outside walls ("sweating") and forces the compressor to run continuously, wasting electricity.


    7. What is the "Cam-Lock" system and why is it important?

    Cam-locks are eccentric hook mechanisms embedded inside the foam of the panels.

    • Assembly: During installation, an Allen key is used to turn the lock, pulling the male and female edges of two panels tightly together.

    • Importance: This creates a tight mechanical seal without relying solely on glue or screws. It prevents "thermal bridges" (gaps where heat enters) and allows the cold room to be disassembled and moved to a new location in the future, which makes the asset modular and reusable.

    8. Does a cold room need a special floor?

    • Chiller Rooms: Often use the existing concrete floor if it is level, though an insulated floor is better for efficiency.

    • Freezer Rooms: Must have an insulated floor. If you build a freezer directly on concrete without insulation, the cold will penetrate downward, freezing the moisture in the soil below. This causes the ground to expand and heave (Frost Heave), which can crack the building's foundation and destroy the freezer floor.

    • Finish: The top surface usually uses checkered aluminum plates (anti-slip) or stainless steel for hygiene.


    Part 3: Refrigeration System & Components

    9. What is the difference between Monoblock and Split refrigeration units?

    • Monoblock (All-in-One): The compressor, condenser, and evaporator are built into a single compact unit that hangs through a hole in the wall.

      • Pros: Easiest to install (plug and play), no piping work needed.

      • Cons: Hot air is vented into the surrounding room (unless ducted), and they are generally limited to smaller capacities.

    • Split System: The condensing unit (noisy part) is placed outdoors, and the evaporator (cooling fan) is inside the room. Connected by copper piping.

      • Pros: Keeps noise and heat outside; supports much larger capacities and longer pipe runs.

      • Cons: Requires a certified technician to weld pipes and charge refrigerant.

    10. How does the defrost system work, and why is it necessary?

    Moisture in the air freezes onto the cold evaporator coils, forming ice. If this ice builds up, it blocks airflow, and the room gets warm.

    • Electric Defrost: Heater elements (like in a toaster) are embedded in the coil. The system pauses cooling, turns on heaters to melt the ice, and drains the water away. Common in freezers.

    • Air Defrost: In chiller rooms (above 2°C), the compressor stops, but the fans keep running. The room air melts the frost naturally.

    • Hot Gas Defrost: Hot refrigerant gas from the compressor is diverted backward through the evaporator. This is the fastest and most energy-efficient method but requires complex valving.

    11. Why do cold storage doors have heater wires?

    In freezer rooms, the temperature difference creates condensation around the door frame. This moisture can freeze, effectively welding the door shut.

    • Solution: A resistance heater wire is embedded in the door frame (or the door gasket). It keeps the perimeter just warm enough to prevent condensation and ice formation, ensuring the door can always be opened easily and the rubber seal doesn't tear.

    12. What is a Pressure Relief Port (or Decompression Valve)?

    When a freezer door is opened, warm air rushes in. When the door closes, that air cools down rapidly and shrinks (contracts).

    • The Physics: This contraction creates a vacuum inside the room. Without a relief port, the negative pressure can be so strong that you physically cannot pull the door open, or it might even collapse the ceiling panels inward.

    • The Valve: A small heated vent in the wall that equalizes the pressure automatically, allowing the door to open freely.

    13. Which refrigerants are currently recommended given environmental regulations?

    Old refrigerants like R22 are banned in most places.

    • Current Standard: R404A has been the standard for years but has a high Global Warming Potential (GWP) and is being phased out in Europe and parts of the US.

    • Modern Alternatives: R448A and R449A are popular, non-flammable replacements with lower GWP.

    • Future Proof: CO2 (R744) is becoming the standard for large industrial cold stores. It is natural, highly efficient, and future-proof against regulation, though the equipment is more expensive initially.


    Part 4: Usage & Maintenance

    14. How should I stack products inside the cold room?

    Proper airflow is critical. The cold air must circulate around the products to remove heat.

    • The Rule: Never block the evaporator fans. Leave at least 30-50cm of clearance in front of the fans.

    • Pallets: Keep products on pallets or shelving, not directly on the floor.

    • Walls: Leave a 5-10cm gap between the product and the wall panels to allow air to "envelope" the cargo.

    15. What is an "Air Curtain" and is it worth the cost?

    An air curtain is a fan unit mounted above the door that shoots a high-velocity stream of air downward when the door opens.

    • Function: It creates an invisible barrier that prevents cold air from falling out and warm air/insects from flying in.

    • Worth it? Yes. If the door is opened frequently, an air curtain can pay for itself in energy savings within 1-2 years by reducing the load on the compressor.

    16. Why is there ice building up on the floor or ceiling?

    • Ceiling Ice: Usually indicates an air leak in the roof panel joints or a lack of vapor barrier, allowing humid air to penetrate and freeze.

    • Floor Ice: Often caused by a damaged door seal (warm air enters at the bottom), or a blocked drain line. If the evaporator drain line heater fails, the water from the defrost cycle spills onto the floor and freezes.

    17. How often should the cold room be serviced?

    • Quarterly (Every 3 months): Clean the condenser coils (outdoor unit) to ensure heat rejection. Check door seals for tears.

    • Semi-Annually: Check refrigerant levels (sight glass), oil levels, and electrical connections.

    • Annually: Thorough inspection of the evaporator fans, drain heaters, and calibration of the temperature sensors.


    Part 5: Design & Energy Efficiency

    18. What is "Pull-Down Time"?

    Pull-down time is the duration required to lower the temperature of the products from their incoming temperature to the storage temperature.

    • Calculation: When sizing a unit, you must tell the engineer the "daily product turnover." Putting 10 tons of warm apples into a room requires a much larger compressor than holding 10 tons of already-cold apples.

    • Standard: A standard holding room is usually designed to handle a 10% daily product turnover with a pull-down time of 18-24 hours.

    19. How can I reduce the electricity bill for my cold storage?

    • Door Management: This is the #1 energy loss. Install automatic door closers or strip curtains (PVC strips).

    • LED Lighting: Use LED lights specifically designed for cold rooms. Old incandescent bulbs add heat to the room, which the compressor then has to remove.

    • Night Blind/Covers: If open display cabinets are used inside, cover them at night.

    • Smart Defrost: Upgrade to a controller that defrosts "on demand" rather than on a fixed timer.

    20. Can I monitor the cold room remotely?

    Yes, this is highly recommended for food safety compliance.

    • IoT Solutions: Modern controllers (like Dixell XWEB or Carel Boss) connect to the internet.

    • Alerts: You can receive SMS or email alerts if the temperature rises above a set limit ("High Temp Alarm"), if the door is left open, or if the power goes out. This allows you to save the inventory before it spoils.

    Leave Your Message
    Write your message here and send it to us

    Related PRODUCTS

    • LAC04-10.0 Cold Room indoor Unit

    • Ammonia evaporative condenser for cold storage

    • 20mm/30mm Insulation PVC Cold room swing door

    • Air-cooled Liquid Chiller

    • Waterproof Cold Room Electric Control Panel

    • Cold Room Control Panel

    Facebook

    Twitter

    Instagram

    Linkedin

    Pinterest

    Youtube

    whatsapp

    Email

    Phone