Shanghai Tech Limited Co.,Ltd

Electric Defrost Cold Room Indoor Unit

Short Description:

Our Electric Defrost Cold Room Indoor Unit is the core component of cold storage systems, suitable for food cold storage, industrial warehouses and commercial cold rooms. Features low noise, stable operation and easy installation, perfect for all cold room cooling needs....


  • Model: LAC02-6.4
  • Power supply: 3N/380V/50HZ
  • Temperature used: -10°C ~ -25°C
  • Refrigeration capacity(kw): 2.2
  • Fin spacing(mm): 6.4

Product Details

Technical Data

FAQ

Product Tags

Description of Electric Defrost Cold Room Indoor Unit

Vegetable Cold Room Indoor Unit
This Electric Defrost Cold Room Indoor Unit is a high-efficiency ceiling‑mounted evaporator designed for stable, uniform cooling in commercial and industrial cold storage. It integrates reliable electric defrosting, optimized heat exchange, and durable construction to maintain consistent temperatures while minimizing frost buildup and energy waste.
Built with high‑quality copper tubes and hydrophilic aluminum fins processed by mechanical expansion, the coil delivers low thermal resistance and strong heat transfer performance. The unit is equipped with a built‑in stainless‑steel electric defrost system that provides fast, even defrosting with short cycle times and minimal temperature fluctuation inside the cold room.

Characteristics of Electric Defrost Cold Room Indoor Unit

Fruit Cold Room Indoor Unitr

High Efficiency Heat Exchanger Design

The unit uses high-quality inner grooved copper tubes and corrugated aluminum fins to form an efficient evaporator coil. The inner grooved copper tubes increase the heat exchange area and improve the flow of refrigerant, which enhances cooling efficiency by more than 30% compared with smooth copper tubes. The corrugated aluminum fins adopt a secondary flanging process and mechanical expansion technology, so that the fins and copper tubes are closely combined without gaps, reducing thermal resistance and improving heat transfer efficiency. The coil is designed with reasonable fin spacing, which can reduce frost accumulation and make defrosting more thorough. The coil undergoes strict air tightness testing under high pressure to ensure no leakage and long-term stable operation.

Bakery Cold Room Indoor Unit

Stable and Efficient Electric Defrost System

The unit is equipped with a high-performance electric defrost system, which is the core advantage of the product. The defrost heater is made of stainless steel, with high insulation, high temperature resistance, and long service life. The heaters are evenly distributed among the coil fins and inside the water tray, ensuring that frost can be melted quickly and completely. The defrost process is controlled by an intelligent temperature control system, which can automatically start and stop according to the frosting degree, avoiding unnecessary energy consumption.

Medical Cold Room Indoor Unit

High Performance Fan and Air Supply System

The unit adopts low noise, energy saving, and long service life external rotor axial fans. These fans are designed for low temperature environments, with strong moisture resistance, stable operation, and long continuous working time. The fan has large air volume and long air supply distance, which can realize uniform air distribution in the whole cold room, avoid local temperature difference, and ensure consistent cooling effect in all areas. The fan shell and blades are made of anti-corrosion materials, which are not easy to rust or deform in a humid and low temperature environment. The fan runs with low vibration and low noise, creating a quiet operating environment.

Storage Cold Room Indoor Unit

Sturdy Structure and Anti Corrosion Performance

The shell of the unit is made of high-quality galvanized steel plate or aluminum magnesium alloy plate, with surface spraying treatment, which has good anti-corrosion, anti-oxidation, and anti-fouling performance. The structure is firm and not easy to deform, adapting to long-term use in harsh cold storage environments. The unit adopts a ceiling mounted structure, which is easy to install and does not take up indoor space. It is equipped with standard mounting brackets and accessories, suitable for various cold room installation conditions. The internal layout is compact, and all parts are easy to access, which is convenient for daily inspection, cleaning, and maintenance.

Applications of Electric Defrost Cold Room Indoor Unit
Distribution Cold Room Indoor Unit

· PrFood processing workshops

· Cold stores and freezer rooms

· Cold chain logistics centres and distribution warehouses

· Pharmaceutical factories and cleanrooms

· Biological laboratories and sample repositories

· Flower preservation chambers

· Low-temperature storage for




  • PREVIOUS:PVC Cold Storage swing door
  • NEXT:Walk-in Cold Room Indoor Unit

  • Model LAC02-6.4

    Inlet refrigerant(mm)

    12

    Power supply

    3N/380V/50HZ Outlet refrigerant(mm)
    22
    Temperature used -10°C ~ -25°C Defrost
    Electric defrost
    Refrigeration capacity(kw) 2.2 Defrost heating(kw)
    2.0
    Fin spacing(mm) 6.4 Air delivery(m)
    9
    Heat transfer area(m2) 6.1

    Weight(kg)

    22
    Number of fans
    1 Operating weight(kg)
    25
    Motor power(w)
    120 Length(mm)
    780
    Fan diameter(mm)
    330 Width(mm)
    370
    Air volume(m3/h)
    1800 Height(mm)
    480

    Description of Unit Cooler Control

    Unit Cooler Control:

    Control encompasses both fan and defrost functions. The evaporator fan operates continuously within the system. Upon initiation of defrosting, the fan shuts off whilst the defrost heater activates.

    When the defrost timer reaches the preset time, the defrost heating element ceases operation
    when the defrost timer reaches the preset time and the internal temperature of the cooling unit reaches the target temperature, the fan commences operation.


    Defrost time setting of Unit Cooler:

    Defrosting occurs four times daily, with an initial default defrost duration of 50 minutes per cycle (adjustable based on actual frost thickness). Following each defrost cycle, the compressor and fan operation is determined by the storage temperature. Electric heating ceases when the interior reaches 15°C; the fan activates when the interior temperature drops to -8°C.

    Comprehensive FAQ: Refrigerated Cabinet

    I. Fundamentals and Components

    1. What is the primary function of a Cold Room Indoor Unit (Evaporator)?

    The primary function of the Cold Room Indoor Unit, commonly called the Evaporator or Unit Cooler, is to absorb heat from the cold room air. It achieves this by causing the low-pressure, low-temperature refrigerant within its coils to undergo a phase change (evaporation from liquid to gas), which is a highly endothermic (heat-absorbing) process, thereby lowering the temperature of the circulating air.

    2. What are the key components of a typical Unit Cooler?

    The main components are:

    • Evaporator Coil: The heat exchanger (copper/aluminum tubes with fins) where the refrigerant evaporates.

    • Fan Assembly: Uses axial or centrifugal fans to force air circulation across the coil and distribute cooled air throughout the room.

    • Defrost System: Typically electric heaters or hot gas lines to melt accumulated frost/ice.

    • Drain Pan (Drip Tray): Collects condensate and meltwater during the defrost cycle.

    • Casing: Corrosion-resistant enclosure (e.g., powder-coated steel, aluminum, stainless steel).

    3. Why is the fin spacing (fin pitch) important, and how does it relate to the room temperature?

    The fin pitch (distance between fins) affects both the heat transfer area and the rate of frost accumulation.

    • High-Temperature Rooms (e.g., above $0^\circ\text{C}$): Smaller fin pitches (e.g., $4.5-6 \text{ mm}$) are used to maximize heat transfer efficiency, as frost formation is minimal.

    • Low-Temperature Rooms (e.g., below $-18^\circ\text{C}$): Wider fin pitches (e.g., $8-12 \text{ mm}$) are necessary to accommodate a thicker frost layer before it significantly impedes airflow, thereby prolonging the time between necessary defrost cycles.

    4. What material is commonly used for evaporator coils and why?

    Copper tubing and aluminum fins are the most common combination due to their excellent thermal conductivity and cost-effectiveness. Stainless steel is sometimes used in highly corrosive environments (e.g., seafood processing) but is more expensive. The fins are bonded to the tubes to ensure maximum heat transfer area.

    5. What is "superheat," and why is it monitored at the evaporator outlet?

    Superheat is the amount of heat added to the refrigerant vapor after it has fully evaporated. It is measured as the temperature of the vapor leaving the evaporator coil minus the saturation temperature (boiling point) of the refrigerant at the evaporator pressure. Maintaining a controlled level of superheat (typically $4 \text{K}$ to $7 \text{K}$) ensures that no liquid refrigerant (liquid slugging) returns to the compressor, which would cause severe damage.

    II. Operation and Performance

    6. How is the cooling capacity (refrigeration capacity) of an evaporator rated?

    The cooling capacity is rated in kW or BTU/hr and is primarily determined by:

    • The temperature difference between the cold room air and the refrigerant evaporation temperature ($\Delta t$).

    • The airflow rate of the fans ($\text{m}^3/\text{h}$ or $\text{CFM}$).

    • The heat transfer surface area (coil size, fin pitch, and design).

    • Crucially: Evaporator capacity is always specified for a given TD (Temperature Difference).

    7. What is the "TD" (Temperature Difference) in relation to the evaporator?

    The TD is the difference between the cold room air temperature and the refrigerant's evaporation temperature ($\text{TD} = T_\text{air} - T_\text{evaporation}$). A smaller TD generally results in higher air humidity and better product quality (less dehydration), but requires a physically larger and more expensive evaporator. A larger TD leads to higher dehydration rates and potentially better energy efficiency but can stress the stored product.

    8. How does frost formation impact the efficiency of the evaporator?

    Frost formation has two major negative impacts:

    • Insulation: The layer of ice acts as an insulator, significantly reducing the heat transfer rate from the air to the refrigerant.

    • Airflow Restriction: The frost clogs the spaces between the fins, dramatically increasing the fan's static pressure and reducing the airflow, leading to poor heat absorption and temperature gradients in the room.

    9. What are the common types of defrost systems used in cold room evaporators?

    The three most common types are:

    • Electric Defrost: Uses electric resistance heaters (sheathed stainless steel elements) embedded within the coil and drain pan. It is the most common and reliable method but consumes significant electrical energy.

    • Hot Gas Defrost: Diverts the high-pressure, high-temperature discharge gas from the compressor into the evaporator coil, using the refrigerant's heat to melt the frost. This is highly efficient and quick but adds complexity to the piping and control system.

    • Air Defrost: Used only in high-temperature rooms (above $0^\circ\text{C}$), where the fans are simply run without refrigeration, allowing the warmer room air to melt the light frost.

    10. Why is it important to insulate the drain pan?

    Insulating or adopting a double-skin design for the drain pan prevents external condensation (sweating) on the pan's underside. If the pan's outer surface is exposed to the humid, slightly warmer room air, water will condense and drip onto the floor or product, which is a major hygiene and safety concern.

    III. Selection and Installation

    11. What is "air throw" or "air projection," and why is it important during installation?

    Air throw is the distance the cooled air jet can effectively travel from the evaporator fans before its velocity and cooling effect diminish. A Unit Cooler must be selected with sufficient air throw to ensure the cooled air reaches the furthest wall of the cold room and promotes uniform air distribution, preventing the formation of warm spots or temperature gradients.

    12. What factors must be considered when selecting an evaporator model?

    Selection must be based on:

    • Required Cooling Capacity: Must match the total calculated heat load (kW).

    • Cold Room Temperature: Dictates the TD and required fin pitch/defrost type.

    • Air Throw/Fan Type: Must suit the dimensions of the room (especially length).

    • Defrost Type: Electric, hot gas, or air defrost.

    • Refrigerant Type: Must be compatible with the system (e.g., R-404A, R-448A, $\text{CO}_2$).

    • Installation Height/Access: Physical size and maintenance clearances.

    13. What is the role of the expansion valve (TXV/EEV) in relation to the indoor unit?

    The Expansion Valve (TXV - Thermostatic Expansion Valve or EEV - Electronic Expansion Valve) is typically installed just before the evaporator. Its role is to:

    • Throttle (Reduce) the pressure of the liquid refrigerant from the condensing unit.

    • Meter (Control) the flow rate of liquid refrigerant into the evaporator coil.

    • It ensures the evaporator coil is fed with the correct amount of refrigerant to maintain the desired superheat (ensure all liquid evaporates before leaving the coil).

    14. How should the drain line be installed to prevent freezing in a freezer room?

    In low-temperature rooms, the drain line must be installed with a continuous downward slope and equipped with heat tracing cable (electric heating wire) along its entire length, especially where it exits the cold room boundary. A trap (U-bend) may be necessary but must also be heated to prevent the meltwater from freezing and blocking the line.

    15. What are the advantages of using variable speed fans on the indoor unit?

    Variable speed fans (often controlled by EC motors) offer several benefits:

    • Energy Savings: The fan speed can be reduced once the setpoint temperature is reached, drastically cutting power consumption.

    • Humidity Control: Lower fan speeds result in a smaller TD, which helps maintain higher relative humidity, reducing product dehydration (weight loss).

    • Noise Reduction: Lower speeds significantly decrease operational noise.

    IV. Maintenance and Troubleshooting

    16. What is the most common reason for a cold room to be running warm despite the unit running continuously?

    The most common reasons are:

    • Severe Frosting: Excessive frost on the coil due to a defrost system failure or inadequate frequency, severely blocking airflow and heat transfer.

    • Low Refrigerant Charge: Insufficient refrigerant in the system reduces the capacity of both the condenser and evaporator.

    • Dirty Coil: Dust, dirt, or debris on the coil surface acting as an insulator.

    • Air Leakage: Excessive infiltration of warm, humid ambient air through poorly sealed doors or panels.

    17. Why is regular cleaning of the evaporator coil necessary?

    Regular cleaning is vital because dust, dirt, or mold can settle on the fins. This debris acts as an insulator, reducing the coil's heat transfer efficiency. In food storage, it is also a critical hygiene requirement to prevent the growth of bacteria and cross-contamination.

    18. How often should the defrost cycle be initiated?

    The frequency depends on the room temperature, the product stored, and the ambient conditions (how frequently the doors open).

    • General Practice: Typically 2 to 6 defrost cycles per 24 hours.

    • High-Humidity Applications: More frequent defrosts (e.g., every 3-4 hours) may be required to prevent rapid frost buildup. The goal is to defrost before the frost layer causes a $20-30%$ reduction in cooling capacity.

    19. What should be done if water is dripping from the evaporator casing outside of the defrost cycle?

    This is usually caused by sweating (external condensation). The solution involves:

    • Checking Drain Pan Insulation: Ensure the drain pan's exterior surface is not exposed to the room air.

    • Checking Casing Integrity: Ensure the main unit casing is well-insulated, and no cold air is leaking through seams to cool the external surface.

    • Inspecting for Blockages: Ensure the drain line is not partially blocked, causing water to back up and overflow.

    20. What is the distinction between a 'Unit Cooler' and a 'Coil Unit'?

    While often used interchangeably:

    • Coil Unit (Evaporator Coil): Refers specifically to the heat exchanger component (tubes and fins) itself.

    • Unit Cooler (Cold Room Indoor Unit): Refers to the complete assembly, which includes the coil, fans, casing, drip tray, and often the defrost heaters—a functional, ready-to-install product.



    Leave Your Message
    Write your message here and send it to us

    Related PRODUCTS

    • Customized Mobile Cold Room

    • Large capacity evaporator indoor unit

    • Cold Storage Room Control Panel

    • Medium Temperature Screw Chiller

    • Modular Screw Chiller

    • Refrigerated container

    Facebook

    Twitter

    Instagram

    Linkedin

    Pinterest

    Youtube

    whatsapp

    Email

    Phone