Shanghai Tech Limited Co.,Ltd

Mandarin Orange Cold Room

Short Description:

Minimize pitting and weight loss in mandarins. Our specialized cold rooms maintain precise 4°C-7°C temperatures and 90% humidity to ensure long-term freshness without cold damage....


  • Product Type:: Mandarin Orange Cold Room
  • Structure:: Assembled
  • Usage:: Meat, Fish, Food, Fruit, Chicken, Vegetables
  • Certification:: RoHS, ISO, CE
  • Condition:: New

Product Details

Technical Data

FAQ

Product Tags

Description of the Mandarin Orange Cold Room

corrosion resistant cold room

Our Mandarin Orange Cold Room is a professional refrigerated storage solution purpose-built for long‑term, high‑quality preservation of mandarins, tangerines, and other citrus fruits. It delivers precise temperature control at 3–5°C and stable humidity at 85%–90% to slow respiration, reduce water loss, and maintain firm texture, bright color, and natural sweetness.
Designed with energy‑efficient cooling units, intelligent digital monitoring, and food‑grade insulated panels, this cold room minimizes decay and extends shelf life up to 3–4 months. It supports flexible sizing from small‑holder storage to large‑scale commercial warehouses, with customizable layouts, airflow systems, and access doors for safe loading, unloading, and daily management.
Built to meet international food storage standards, it is widely used in citrus orchards, packing houses, distributors, and export supply chains to secure freshness, reduce post‑harvest loss, and stabilize market supply year‑round.

Core characteristics of Mandarin Orange Cold Room

mobile cold room

Uniform Air Circulation & Anti-Mold Preservation

A well-designed air circulation system ensures even temperature and humidity distribution across every corner of the cold room, eliminating hotspots or uneven cooling that could damage stored fruit. Optimized air duct layout and adjustable air volume allow gentle, consistent airflow that does not directly blow onto the mandarin oranges, preventing peel damage and water loss.
This uniform ventilation system effectively reduces the accumulation of ethylene gas released by mandarin oranges. Ethylene accelerates ripening and aging; therefore, timely dilution and discharge of ethylene are essential for extending shelf life. Combined with the appropriate low-temperature and humidity environment, the cold room suppresses the growth and reproduction of mold and spoilage bacteria, greatly reducing rot rates during storage. Mandarin oranges stored inside maintain good hardness, bright color, and natural aroma, effectively extending shelf life from several weeks to several months according to actual operational needs.

container cold room

Food-Grade Insulated Structure & Sealing Design

The cold room adopts high-density polyurethane insulation panels with excellent thermal insulation performance. These panels feature a smooth, food-grade surface that is non-toxic, odorless, corrosion-resistant, and fully compliant with international food safety and hygiene standards. The thick insulation layer effectively blocks external heat transfer, maintains internal temperature stability, reduces the operating load of the refrigeration system, and enhances overall energy efficiency.
The structural panels feature a convenient, firm splicing installation, ensuring good airtightness and structural stability. Equipped with high-quality sealed cold room doors, the unit minimizes cold air leakage during frequent opening and closing. The reliable sealing performance not only saves energy but also prevents external dust, insects, and unclean air from entering the storage space, creating a clean, hygienic, and low-contamination environment for mandarin orange storage.

cold room for sale

Precision Temperature & Humidity Control System

The Mandarin Orange Cold Room is engineered with an intelligent, high-precision temperature and humidity regulation system, specifically designed to preserve the freshness, flavor, and nutritional value of mandarin oranges throughout long-term storage. Unlike general-purpose cold rooms, this unit maintains a stable storage temperature range of 3°C to 5°C, the optimal thermal environment for slowing down the respiration rate of citrus fruits. By suppressing metabolic activity, it effectively delays ripening, softening, and decay, keeping mandarins in their freshest state for an extended period.

cold room factory

Intelligent Control & Easy Operation

The Mandarin Orange Cold Room is equipped with an intelligent digital control panel that features high-definition display, sensitive response, and intuitive operation. Users can easily set and adjust target temperature, humidity, and operating modes with simple operations. The system supports real-time monitoring of internal environmental parameters, allowing managers to stay informed of storage conditions at any time.
It also includes complete alarm functions, such as high-temperature alarm, low-temperature alarm, sensor failure alarm, and system fault alarm. Once abnormal conditions occur, the system immediately alerts the operator to take timely measures, avoiding large-scale fruit loss due to equipment malfunction or improper settings. The user-friendly control interface requires minimal professional training, making the cold room easy to operate for both small agricultural bases and large-scale logistics and distribution centers.

Applications of Mandarin Orange Cold Room
cold room exporter

· PrFood processing workshops

· Cold stores and freezer rooms

· Cold chain logistics centres and distribution warehouses

· Pharmaceutical factories and cleanrooms

· Biological laboratories and sample repositories

· Flower preservation chambers

· Low-temperature storage for




  • PREVIOUS:Lettuce Cold Room
  • NEXT:Strawberry Cold Room

  • Product Type Mandarin Orange Cold Room
    Structure
    Assembled
    Usage
    Meat, Fish, Food, Fruit, Chicken, Vegetables
    Certification
    RoHS, ISO, CE
    Condition
    New
    Cold Room Panels
    PU Foam Core Sandwich Panel/PlR (Polyisocyanurate)Foam Core Sandwich Panel
    Surface Treatment
    Color Steel/Stainless Steel/Stucco Embossed Aluminum
    Floor
    PU Panel / Concrete with XPS / Checker Plate
    Refrigeration System
    New Generation Smart Cooling System
    Compressor
    Bitzer
    Evaporator
    Air Cooled (Ceiling Mounted, Floor Mounted)
    Energy Effciency
    Grade l
    Service Door
    Customized
    Product Name
    Movable Portable Cold Room for Food and Drug Trans
    Specification
    Customized

    Comprehensive FAQ: Cold Storage Rooms & Walk-in Freezers

    Part 1: General Definitions & Types

    1. What is the difference between a Cold Storage Room (Chiller) and a Freezer Room?

    While both look structurally similar, the key difference lies in temperature range and application:

    • Chiller Room (Medium Temperature): Operates between 0°C and +5°C (32°F - 41°F). It is designed to preserve fresh products like vegetables, fruits, dairy, and beverages without freezing them. The goal is to slow down bacterial growth and enzymatic activity.

    • Freezer Room (Low Temperature): Operates between -18°C and -25°C (0°F - -13°F). It is designed to keep products frozen solid (meat, fish, ice cream). The refrigeration system requires more power, thicker insulation, and specific defrosting mechanisms compared to a chiller.

    2. What is a "Blast Freezer" and how does it differ from a standard freezer?

    A standard freezer is designed for holding already-frozen goods. A Blast Freezer (or Shock Freezer) is designed for processing.

    • Function: It uses high-velocity fans and powerful compressors to pull the temperature of fresh food down to -18°C core temperature extremely fast (usually within 4 to 6 hours).

    • Why use it? Rapid freezing creates "micro-crystals" inside the food cells. Slow freezing creates large jagged ice crystals that puncture cell walls, causing "drip loss" and mushy texture upon thawing. Blast freezing preserves the quality, texture, and nutritional value of the food.

    3. What is a "CA" (Controlled Atmosphere) Cold Store?

    A Controlled Atmosphere (CA) store is an advanced cold room typically used for long-term fruit storage (like apples, pears, or kiwis).

    • Mechanism: In addition to controlling temperature, a CA room tightly controls the gas composition of the air. It reduces Oxygen (O2) and increases Carbon Dioxide (CO2) and Nitrogen.

    • Benefit: This puts the fruit into a state of "hibernation," slowing down its respiration rate. This allows seasonal fruits to be stored for 6 to 9 months and sold year-round as if they were fresh.

    4. Can I use a standard air conditioner (AC) to cool a small cold room?

    No. This is a common mistake that leads to equipment failure.

    • Design Difference: Standard AC units are designed to cool air to roughly 18°C-22°C. They are not designed to handle the moisture load or the low temperatures of a cold room (0°C).

    • The Result: If you force an AC to run at 5°C, the evaporator coil will freeze up immediately because it lacks a defrost mechanism. Furthermore, the compressor is not designed for the pressure ratios required for refrigeration, leading to premature burnout.


    Part 2: Structure & Insulation

    5. Why are Polyurethane (PU) panels the industry standard for cold rooms?

    Polyurethane is used because it offers the best strength-to-insulation ratio.

    • Thermal Efficiency: PU has an extremely low thermal conductivity (K-value roughly 0.022 W/mK), meaning it keeps heat out very effectively.

    • Structural Integrity: When "sandwiched" between steel sheets, high-density PU foam (40-42 kg/m³) becomes rigid enough to support the ceiling and walls without needing an external skeleton for small to medium rooms.

    • Hygiene: PU panels are moisture-resistant and do not rot or harbor mold, which is critical for food safety standards (HACCP).

    6. How do I determine the correct panel thickness?

    Thickness depends on the temperature difference between the inside of the room and the outside ambient air. General guidelines are:

    • Chiller Rooms (0°C to +5°C): Typically use 75mm or 100mm thick panels.

    • Freezer Rooms (-18°C to -25°C): Typically use 120mm or 150mm thick panels.


    • Blast Freezers (-40°C): Require 150mm or 200mm panels.
      Using panels that are too thin causes condensation on the outside walls ("sweating") and forces the compressor to run continuously, wasting electricity.


    7. What is the "Cam-Lock" system and why is it important?

    Cam-locks are eccentric hook mechanisms embedded inside the foam of the panels.

    • Assembly: During installation, an Allen key is used to turn the lock, pulling the male and female edges of two panels tightly together.

    • Importance: This creates a tight mechanical seal without relying solely on glue or screws. It prevents "thermal bridges" (gaps where heat enters) and allows the cold room to be disassembled and moved to a new location in the future, which makes the asset modular and reusable.

    8. Does a cold room need a special floor?

    • Chiller Rooms: Often use the existing concrete floor if it is level, though an insulated floor is better for efficiency.

    • Freezer Rooms: Must have an insulated floor. If you build a freezer directly on concrete without insulation, the cold will penetrate downward, freezing the moisture in the soil below. This causes the ground to expand and heave (Frost Heave), which can crack the building's foundation and destroy the freezer floor.

    • Finish: The top surface usually uses checkered aluminum plates (anti-slip) or stainless steel for hygiene.


    Part 3: Refrigeration System & Components

    9. What is the difference between Monoblock and Split refrigeration units?

    • Monoblock (All-in-One): The compressor, condenser, and evaporator are built into a single compact unit that hangs through a hole in the wall.

      • Pros: Easiest to install (plug and play), no piping work needed.

      • Cons: Hot air is vented into the surrounding room (unless ducted), and they are generally limited to smaller capacities.

    • Split System: The condensing unit (noisy part) is placed outdoors, and the evaporator (cooling fan) is inside the room. Connected by copper piping.

      • Pros: Keeps noise and heat outside; supports much larger capacities and longer pipe runs.

      • Cons: Requires a certified technician to weld pipes and charge refrigerant.

    10. How does the defrost system work, and why is it necessary?

    Moisture in the air freezes onto the cold evaporator coils, forming ice. If this ice builds up, it blocks airflow, and the room gets warm.

    • Electric Defrost: Heater elements (like in a toaster) are embedded in the coil. The system pauses cooling, turns on heaters to melt the ice, and drains the water away. Common in freezers.

    • Air Defrost: In chiller rooms (above 2°C), the compressor stops, but the fans keep running. The room air melts the frost naturally.

    • Hot Gas Defrost: Hot refrigerant gas from the compressor is diverted backward through the evaporator. This is the fastest and most energy-efficient method but requires complex valving.

    11. Why do cold storage doors have heater wires?

    In freezer rooms, the temperature difference creates condensation around the door frame. This moisture can freeze, effectively welding the door shut.

    • Solution: A resistance heater wire is embedded in the door frame (or the door gasket). It keeps the perimeter just warm enough to prevent condensation and ice formation, ensuring the door can always be opened easily and the rubber seal doesn't tear.

    12. What is a Pressure Relief Port (or Decompression Valve)?

    When a freezer door is opened, warm air rushes in. When the door closes, that air cools down rapidly and shrinks (contracts).

    • The Physics: This contraction creates a vacuum inside the room. Without a relief port, the negative pressure can be so strong that you physically cannot pull the door open, or it might even collapse the ceiling panels inward.

    • The Valve: A small heated vent in the wall that equalizes the pressure automatically, allowing the door to open freely.

    13. Which refrigerants are currently recommended given environmental regulations?

    Old refrigerants like R22 are banned in most places.

    • Current Standard: R404A has been the standard for years but has a high Global Warming Potential (GWP) and is being phased out in Europe and parts of the US.

    • Modern Alternatives: R448A and R449A are popular, non-flammable replacements with lower GWP.

    • Future Proof: CO2 (R744) is becoming the standard for large industrial cold stores. It is natural, highly efficient, and future-proof against regulation, though the equipment is more expensive initially.


    Part 4: Usage & Maintenance

    14. How should I stack products inside the cold room?

    Proper airflow is critical. The cold air must circulate around the products to remove heat.

    • The Rule: Never block the evaporator fans. Leave at least 30-50cm of clearance in front of the fans.

    • Pallets: Keep products on pallets or shelving, not directly on the floor.

    • Walls: Leave a 5-10cm gap between the product and the wall panels to allow air to "envelope" the cargo.

    15. What is an "Air Curtain" and is it worth the cost?

    An air curtain is a fan unit mounted above the door that shoots a high-velocity stream of air downward when the door opens.

    • Function: It creates an invisible barrier that prevents cold air from falling out and warm air/insects from flying in.

    • Worth it? Yes. If the door is opened frequently, an air curtain can pay for itself in energy savings within 1-2 years by reducing the load on the compressor.

    16. Why is there ice building up on the floor or ceiling?

    • Ceiling Ice: Usually indicates an air leak in the roof panel joints or a lack of vapor barrier, allowing humid air to penetrate and freeze.

    • Floor Ice: Often caused by a damaged door seal (warm air enters at the bottom), or a blocked drain line. If the evaporator drain line heater fails, the water from the defrost cycle spills onto the floor and freezes.

    17. How often should the cold room be serviced?

    • Quarterly (Every 3 months): Clean the condenser coils (outdoor unit) to ensure heat rejection. Check door seals for tears.

    • Semi-Annually: Check refrigerant levels (sight glass), oil levels, and electrical connections.

    • Annually: Thorough inspection of the evaporator fans, drain heaters, and calibration of the temperature sensors.


    Part 5: Design & Energy Efficiency

    18. What is "Pull-Down Time"?

    Pull-down time is the duration required to lower the temperature of the products from their incoming temperature to the storage temperature.

    • Calculation: When sizing a unit, you must tell the engineer the "daily product turnover." Putting 10 tons of warm apples into a room requires a much larger compressor than holding 10 tons of already-cold apples.

    • Standard: A standard holding room is usually designed to handle a 10% daily product turnover with a pull-down time of 18-24 hours.

    19. How can I reduce the electricity bill for my cold storage?

    • Door Management: This is the #1 energy loss. Install automatic door closers or strip curtains (PVC strips).

    • LED Lighting: Use LED lights specifically designed for cold rooms. Old incandescent bulbs add heat to the room, which the compressor then has to remove.

    • Night Blind/Covers: If open display cabinets are used inside, cover them at night.

    • Smart Defrost: Upgrade to a controller that defrosts "on demand" rather than on a fixed timer.

    20. Can I monitor the cold room remotely?

    Yes, this is highly recommended for food safety compliance.

    • IoT Solutions: Modern controllers (like Dixell XWEB or Carel Boss) connect to the internet.

    • Alerts: You can receive SMS or email alerts if the temperature rises above a set limit ("High Temp Alarm"), if the door is left open, or if the power goes out. This allows you to save the inventory before it spoils.

    Leave Your Message
    Write your message here and send it to us

    Related PRODUCTS

    • Customized Design Walk In Freezer Door

    • Potato Cold Storage

    • Cold Room

    • Corrosive environment air cooled chiller

    • Pork Cold Room

    • Medium-Low Temp Refrigeration Unit

    Facebook

    Twitter

    Instagram

    Linkedin

    Pinterest

    Youtube

    whatsapp

    Email

    Phone